ISO 594-2 PDF

Scope: ISO specifies requirements for conical lock fitting with a 6% (Luer) taper for use with hypodermic syringes and needles and with certain other. Smithers Pira tests conical (Luer) fittings to ISO , assessing their characteristics and functional performance against the requirements set out in the . ISO. INTERNATIONAL. STANDARD. Second edition. Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical.

Author: Dular Balabar
Country: Thailand
Language: English (Spanish)
Genre: Finance
Published (Last): 19 August 2007
Pages: 443
PDF File Size: 2.47 Mb
ePub File Size: 3.17 Mb
ISBN: 957-9-67992-782-4
Downloads: 91734
Price: Free* [*Free Regsitration Required]
Uploader: Meshicage

Torsion Add On 2. Email addresses must contain the symbol. For testing of separation force and unscrewing torque, take a look at 54-2 Bluehill LE for Basic Testing.

ISO/2; Conical Fittings with 6% (Luer) Taper

If accuracy is critical, base your final 5942- on the data provided in the root documents: Top Gage Crib Worldwide, Inc. Force ratings up to 2. By means of our testing expertise and modular product design, we will help find the solution that is right for you.

Software for Series Systems.

We are confident that we have what you are looking for. ISO is the standard specification and test method for the design of such Luer taper fittings. An Electromechanical system with a torsion add-on can be used to perform these tests. The ease of assembly test method that was part of the ISO series has been removed as a requirement from the application parts of ISO and is not present in this part of ISO Contact Us View Accessories Catalog.

  EN 1254-3 PDF

Conical Luer fittings are commonly used in medical devices, such as syringes, hypodermic needles, and catheters, to achieve a leak-free connections between medical devices. A biaxial Dynacell load cell is mounted to the base of the machine.

ISO 594-1 & 2 Separation Force and Unscrewing Torque Testing for Luer Tapers

Ensures that the specimen Luer remains attached under a specific unscrewing torque in the counterclockwise direction. Gage Crib Worldwide, Inc. This stress cracking test method is performed in the same manner as in the ISO series.

Ensures that the threads cannot be overridden by a specific screwing torque in the assembly clockwise direction. Unscrewing torque is tested by applying a 0.

ISO & 2 Separation Force and Unscrewing Torque Testing for Luer Tapers

A Luer lock contains a Luer slip fitting with threads that can be connected. WaveMatrix 2 for Dynamic Testing.

Give our test engineers a call today for help configuring the best test machine and accessories according to your standard. ISO provides test methods for testing the separation force of Luer fitting assemblies and unscrewing torque of Luer fitting assemblies. Ensures that the Luer specimen can be assembled with minimum axial force and torque. Ensures that the Luer specimen remains attached to the reference fitting when an axial load is applied.

Resistance to Separation from Unscrewing Test Method. Subscribe to Our Newsletters. This resistance to separation from unscrewing test method is performed in the same manner as the 954-2 series. This resistance to overriding test method is performed in the same manner as the ISO series. By continuing to use our site, you accept our cookie policy. The rationale given in Annex A; Paragraph A. 59-2 a question about conducting the test for this standard?

  ALGEMENE RELATIVITEITSTHEORIE PDF

Separation force 54-2 tested by applying a tensile axial force from a fatigue test machine.

ISO 594 Testing of Conical Luer Fittings

For all tests in ISO requiring an assembled Luer fitting, fittings are assembled using an axial torsion machine, applying a compressive force not greater than Furthermore, the intent of the ease of assembly test was to ensure that the io can complete the connection using the mating halves of the connector.

This data is provided for general information only. It was under kso for a standardized test method, i. A Luer slip is a tapered cone that connects to a tapered cavity.

This resistance to separation from axial load test method is performed in the same manner as in the ISO series. Concrete, Asphalt and Rock.

This subatmospheric-pressure air leakage test method isi a new test method that was not part of the former ISO series. A slight axial load can be placed on the bottle cap to push it down before rotation begins. This requirement is satisfied by the requirement for usability validation for all new connectors being added to ISO