FLUKE 8505A PDF

Fluke A Digital Multimeter DIGIT Engineering Bench Precision OPT 02a 03 About this product. About this product. Product Identifiers. BRAND. Fluke. Full text of “FLUKE A Instruction”. See other formats. Instruction Manual P/N MARCH 1 REV 1, 3/86 ®, John Fluke Mfg. Co., Inc. All Rights. Active Filter Block Diagram A Fast A/D Converter The Fast A/ D Converter employs Fluke’s patented recirculating remainder (R2) technique.

Author: Gujind Zulkikora
Country: Comoros
Language: English (Spanish)
Genre: History
Published (Last): 17 March 2011
Pages: 410
PDF File Size: 18.86 Mb
ePub File Size: 9.76 Mb
ISBN: 371-3-87647-112-7
Downloads: 24968
Price: Free* [*Free Regsitration Required]
Uploader: JoJojora

Non-marring feet and a tilt-down bail arrangement are installed on the instrument for field or bench use. Speeds up to readings per second are possible in this mode of operation.

Error 9 Function selection error. Module Disassembly and Reassembly Measurement Connections 3- 1. For recall of tluke readings, dates and identifiers, refer to Calibration Mode later in this section.

Pushing ZERO a second time disables the mode, but retains theprevious value. One variety includes dc volts Vohms Zand dc amps I. Reselecting V DC sets autoranging.

Power off; replace or install Analog to Digital Converter module. When initially commanding an ac volts function, only VA for ac coupling orC for dc coupling need be used.

  JOFEMAR J2000 PDF

Scaling and External Reference modes are mutually exclusive: See all 6 pre-owned listings. This command allows the operator to specify the response for an error fpuke. This warranty shall not apply to fuses, disposable batteries rechargeable type batteries are warranted for daysor any product or parts which have been subject to misuse, neglect, accident, or abnormal conditions of operations.

Continuous Line Synchronous To: This eight-section manual provides comprehensive information for installing, operating and mainta inin g your Fluke digital multimeter.

For recall of uncorrected readings, dates and identifiers, refer to Calibration Mode later in this section. This description is followed by Circuit Analysis, which gives a more detailed description of the circuitry. No sample setting is allowed. Error 7 External Reference error – voltage on one input exceeds 20V dc.

Fluke 8505A reference multimeter

If the applications are duplicated, modes or values already programmed could interfere with the expected instrument response. Ratio, deviation, percentage variation and other mathematically manipulated displays are thereby possible.

All active components are contained in modules which plug into a mainframe motherboard. A valid reading is triggered. It does not identify the error.

Fluke 8505A Multimeters

The CAL COR push button is used when storing calibration factors for each function and range, or when recalling uncorrected readings. Flukw the following six digits as the calibration date or the multimeter identification. Error E More than one ac converter, flukr the wrong ac converter, is installed. Programming Instructions cont When each reading is accepted by the instrument controller, the next reading will be started.

  BACKTRACK 5 TESTY PENETRACYJNE SIECI WIFI PDF

Averaging AC Converter Option 2: One value whether a numeric or a previous display may be stored at a time.

Full text of “FLUKE a”

Either mode is valid for any function and range. These modules are fully explained in Section 6. Mathematic operations can be specified to change the measured value as influenced by measurement parameters before it is actually displayed.

The multimeter automatically subtracts a programmed numeric or previously stored display value from the measurement and displays the result. The first and second characters of the status response then identify the error condition by number.